Remembered No
9.6 Set Debounce Time
Syntax
Hexadecimal 0xFE 0x55 [time]
Decimal 254 85 [time]
ASCII 254 “U” [time]
Parameters
Parameter Length Description
time 1 Debounce time in increments of
6.554ms (0 - 255).
Description This command sets the time between key press and key read. All key
types with the exception of latched piezo switches will ’bounce’ for a
varying time, depending on their physical characteristics. The [time]
value is in increments of 6.554ms. The default debounce time for the
module is 8 (about 52ms), which is adequate for most membrane
keypads.
Remembered Yes
Default 8
9.7 Set Auto Repeat Mode
Syntax
Hexadecimal 0xFE 0x7E [mode]
Decimal 254 126 [mode]
ASCII 254 “~” [mode]
Parameters
Parameter Length Description
mode 1 Auto Repeat Mode (0: Resend Key
, 1: Key Up/Down)
Matrix Orbital LK204-25 38