
Command Summary 22
6.7 Set and Save
Contrast
Contrast
Contrast
Contrast
Immediately sets and saves the contrast between background and text. Although contrast can be changed using
the set command, it is reset to this saved value on start up. Default is 128.
Contrast level from 0(Light) to 255(Dark).
6.7 Data Security
Allows changes to specific settings to be saved to the display memory. Writing to non-volatile memory can be slow
and each change consumes 1 write of at least 100,000 available. The Command Summary outlines which
commands are saved always, never, and when this command is on only. Remember is off by default.
254 202 245 160
FE CA F5 A0
■ ╩ ⌡ á
Temporarily locks certain aspects of the display to ensure no inadvertent changes are made. The lock is released
after a power cycle. A new level overrides the old, and levels can be combined. Default is 0.
Lock level, see Data Lock Bits table.
Table 14: Data Lock Bits
Table 15: Lock Parameters
Place holders only, should be 0
Locks the Baud Rate and I2C address
Locks all settings from being saved
Locks all commands, text can still be written
Locks entire display, no new text can be displayed
7.3 Set and Save
Data Lock
254 203 245 160
FE CB F5 A0
■ ╦ ⌡ á
Locks certain aspects of the display to ensure no inadvertent changes are made. The lock is not affected by a
power cycle. A new level overrides the old, and levels can be combined. Default is 0.
See Data Lock Bits table.
Kommentare zu diesen Handbüchern