19
6.4 General Purpose Output
4.1 General Purpose
Output On
Turns the specified GPO on, sourcing current from an output of five volts.
4.2 General Purpose
Output Off
Turns the specified GPO off, sinking current to an output of zero volts.
4.3 Set Start Up
GPO State
Number State
Number State
Number State
Sets and saves the start up state of the specified GPO in non volatile memory. Changes will be seen on start up.
6.5 Dallas One-Wire
5.1 Search for a
One-Wire Device
254 200 2
FE C8 02
■ ╚ SOT
Sends a search query to each of the up to 32 devices on the one wire bus. Any connected device will respond with
an identification packet.
Dallas One-Wire identification packet as shown below.
Table 13: Dallas One-Wire Packet Information
Another device packet will follow OR
Error Code (0 indicates success)
CRC8 address check (0 indicates validity)