23 Command Summary
Red Green Blue
Red Green Blue
Red Green Blue
Set the colour of a tri-colour backlight. Only for tri-colour displays. Default is white (255, 255, 255).
Brightness level of Red from 0(Dim) to 255(Bright).
Brightness level of Green from 0(Dim) to 255(Bright).
Brightness level of Blue from 0(Dim) to 255(Bright).
Contrast
Contrast
Contrast
Immediately sets the contrast between background and text. If an inverse display color is used this also represents
the text brightness. Default is 128.
Contrast level from 0(Light) to 255(Dark).
7.7 Set and Save
Contrast*
Contrast
Contrast
Contrast
Immediately sets and saves the contrast between background and text. Although contrast can be changed using
the set command, it is reset to this saved value on start up. Default is 128.
Contrast level from 0(Light) to 255(Dark).
6.8 Data Security
Allows changes to specific settings to be saved to the display memory. Writing to non-volatile memory can be slow
and each change consumes 1 write of at least 100,000 available. The Command Summary outlines which
commands are saved always, never, and when this command is on only. Remember is off by default.
254 202 245 160
FE CA F5 A0
■ ╩ ⌡ á
Temporarily locks certain aspects of the display to ensure no inadvertent changes are made. The lock is released
after a power cycle. A new level overrides the old, and levels can be combined. Default is 0.
Lock level, see Data Lock Bits table.
Table 16: Data Lock Bits
Table 17: Lock Parameters
Place holders only, should be 0