Matrix-orbital GLK12232-25-SM Bedienungsanleitung Seite 12

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 70
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 11
Power/Connector Regular GLK12232-25-SM input -V option input
Vcc +5V only 9-15V
+5V +5V only N/C
+12V N/C +12V
NOTE +12V is nominal for the -V but supply of 9-15V is acceptable
Figure 11: Power and Data Configuration
To power up and communicate with a GLK12232-25-SM (standard or wide voltage options), the users
have two options for connections:
power and data connections using the Power/Data Connector of the GLK12232-25-SM (supply Vcc
with the proper voltage)
power connections using the Floppy Power connector and data (RX/TX) and ground using the Power/Data
connector
NOTES
A common ground should be used at all times
Each module ordered has specific voltages and cannot be interchanged
Matrix Orbital GLK12232-25-SM 7
Seitenansicht 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 69 70

Kommentare zu diesen Handbüchern

Keine Kommentare